Clamp ammeter is a combination of current transformer and ammeter. The iron core of the current transformer can be opened when the wrench is tightened; the wire through which the measured current passes can pass through the opening of the iron core without cutting it, and the iron core is closed when the wrench is released. The circuit wire under test passing through the iron core becomes the primary coil of the current transformer, in which the current is induced in the secondary coil by passing the current. So that the ammeter connected to the secondary coil will have an indication-----measure the current of the line under test. The clamp meter can be changed to different ranges through the shift of the switch. However, it is not allowed to operate with power on when shifting gears. The accuracy of the clamp meter is generally not high, usually 2.5 to 5 grades. For the convenience of use, there are also switches of different ranges in the meter for measuring different levels of current and measuring voltage.