+86-18822802390

Metalurški mikroskop Upotreba malog povećanja

Apr 22, 2024

Metalurški mikroskop Upotreba malog povećanja

 

1. Poravnavanje svjetla metalurškog mikroskopa

Lijevom rukom okrenite vijak za grubo podešavanje da bi se cijev objektiva podigla ili platforma nosača prema dolje, a zatim zarotirajte pretvarač objektiva kako bi objektiv sa malim povećanjem bio poravnat sa platformom za nosač kroz otvor za svjetlo (rotacija treba biti oprezna da napravite sočivo objektiva iznad nedostatka graviranja i osnove fiksne kopče), otvorite otvor, okrenite vijak za podizanje kolektorske leće, tako da kolektorsko ogledalo na gornjem kraju ravnine sočiva bude nešto niže od visine ravnini nosača platforme, dva oka u isto vrijeme, uz podešavanje smjera reflektora dok vidno polje ne bude ravnomjerno, a svjetlina umjerena.

 

2. Metalografski mikroskopPostavljanje uzorka na stakalcu

Uzmite uzorak stakalca i stavite ga na nosač sa stranom poklopca okrenutom prema gore, pričvrstite ga na potiskivač, a zatim ručno okrenite vijak za potiskivanje da biste poravnali uzorak koji treba promatrati sa središtem otvora.

 

3. Metalografski mikroskopPodešavanje fokusa

Rukom okrenite vijak za grubo podešavanje, napravite sočivo sa malim uvećanjem<6mm from the slide specimen (when adjusting the distance between the objective lens and the slide must be watched from the side, do not turn the coarse adjustment screw at the same time as observing with your eyes on the eyepiece to prevent the lens from colliding with the slide and causing damage), and then open your eyes at the same time, turn the coarse adjustment screw slowly by hand so that the lens rises or make the carrier table fall, when the object image in the field of view is viewed, then adjust the fine adjustment screw until a clear object image appears in the field of view. When the object image appears in the field of view, adjust the fine adjustment screw until a clear object image appears in the field of view. If the object image is not in the centre of the field of view, move the slide specimen up and down, left and right (Note: the direction of movement of the slide is opposite to the direction of movement of the observed object image). If the distance between the lens and the specimen slice has exceeded the working distance when adjusting the focal length and the object image is not seen, then it should be reopened strictly according to the above steps.

 

4 Electronic Magnifier

 

 

 

 

 